Modular Patient Monitor X6

   
 
   
 
Home
Company
Contact
Download
  Products

Features:


Plug-in modular design, all modules support hot plugwith free combination, convenient to use, maintain and upgrade
Professional EEG monitoring to make it more perfect
15/17/19 inch high definition color display
Standard six-parameter module: ECG, HR, NIBP, SpO2, RESPand TEMP
Powerful software functions, to show full range ofinformation reports
3 level intelligent alarms: sound, light and voice alert,volume adjustable
Compatible with central monitoring system
Optional modules: EEG/PSG, EtCO2, IBP, CSI (cerebralstate index);
Expandable EEG or EEG&PSG module for brain functionand polysomngraphic recording:
Independent EEG module is8/16/32 channels optional
Integrated EEG$PSG moduleincluding: EEG(8/16 channels);EOG (2 channels); EMG (1 channel); SNORING (1channel ); AIRFLOW (1 channel ); ABDOMINAL (1 channel )

 

Specifications:

ECG
Lead type:3/5 leads electric cable
Input: 3 leads: RA, LA, LL(Lead method: I, II, III)
5 leads: RA, LA, LL,RL, V (Lead method: I, II, III, aVR, aVL, aVF, V)
Gain:´250, ´500, ´1000, ´2000
Heart rate range: 15~300bpm(adult), 15~350bpm (child & neonate)
Accuracy: ±1bpm or±1%, whichever is bigger
Resolution: 1bpm
Sensitivity: >200uV (peak to peak)
Input impedance: >5MΩ
Bandwidth: Diagnosis model: 0.05~130Hz, Monitoring: 0.5~40Hz,Operation: 1~20Hz
CMRR: Diagnosis model: >90dB, Monitoring model: >100dB,Operation model: >100dB
Electrode polarizationand voltage range:±300mV
Pacemaker impulsesAmplitude: ±2mV~ ±700mV, Width: 0.1ms~2ms, Rise time: 10us~100µs
Recovery time: < 3 seconds
Signal range: ±8 mV peak to peak
Calibrate signal: 1mV peakto peak;accuracy: ±5%
ST detection: Range: -2.0mV~ +2.0Mv, Accuracy: -0.8 mV~+0.8mV, Error: ±0.02mV/±10%
Arrhythmiaanalysis (13 kinds):
NIBP (Noninvasive bloodpressure)
Method: Pulse waveoscillation
Operation mode: Manual/Automatic/Continuous
Time interval (Automatic):1min,2mins, 3mins, 4mins, 5mins, 10mins, 15mins, 30mins, 60mins, 90mins, 2hours,3hours, 4hours, 8hours
Time interval (Continuous): 5mins
Range: Adult:Systolic blood pressure: 40~280mmHg
Diastolicblood pressure: 10~220mmHg
Mean pressure:20~240mmHg
Child: Systolic bloodpressure: 40~220mmHg
Diastolic bloodpressure: 10~160mmHg
Mean pressure:20~170mmHg
Neonate: Systolicblood pressure: 40~135mmHg
Diastolic bloodpressure: 10~100mmHg
Mean pressure:20~110mmHg
Static pressure range:0~300mmHg, Static pressure accuracy:±3mmHg
Maximum average deviation:±3mmHg; Maximum standard deviation:±6mmHg
Over-pressure protection: 300 mmHg(adult), 240 mmHg (child), 150 mmHg (neonate)
SpO2
Range:0~100%
Resolution:1%
Accuracy: ±1% (70~100%), ±2% (40%~69%), notdefined (<39%)
Respiration
Method: RA-LLimpedance
Range of respiratory impedance: 0.3~3Ω
Base impedance range: 200~4000Ω
Bandwidth: 0.1~2.5Hz
Gain: ´0.25, ´0.50, ´1, ´2, ´4
Respiration rate:7~120BrPM(adult), 7~150BrPM (child & neonate)
Resolution: 1BrPM
Accuracy:±2BrPM
Apnea Alarm:10~40second selectable
Temperature
Sensor type: 10K series, 2.25K series
Channels: 2channels
Range: 0~50°C
Resolution: 0.1°C
Accuracy:±0.1°C (25°C ~45°C), ±0.2°C (0°C~25°C, 45°C ~50°C)

   
Ambulance
Infant Incubator
Infant Radiant Warmer
Infant Phototherapy
Jaundice Meter
Patient Monitor
Oximeter
Oxygen Concentrators
Syringe & Infusion Pump
Ultrasound Scanner
ECG Machine
Holter & Stress Test System
Stethoscope
Patient Bed
Ventilator
Ophthalmology
Suction
Endoscope
C-ARM
Anesthetic Machine